:: Industry Wide Problem ::

The loads moved by a typical material handling vehicle come in a variety of different shapes, physical sizes and weights.

The majority of the forklift operators will experience some difficulty with problems relating to the theoretical forklift lifting capacity as indicated on the manufacturer’s ID plate and the unknown load weights that are moved within the material operating facilities.

     

       


When the weight of the load is not clearly marked and the loads are moved to various lifting heights, there is a danger of the vehicle stability. The travel speed and turning radius that cannot be easily judged will have a substantial effect on the load center of the vehicle. The forklift operator must deal with unknown elements that will have an effect on changes in the vehicle’s center of gravity that has moved outside of the "Stability Triangle" without the operator’s knowledge. It is well know that this can result in the possibility of the vehicle tipping which may cause damage to the goods and the equipment as well as compromising the operator’s safety.



         


      


The ED2-SLL Series SkidWeigh is an electronic device that can be installed on any forklift truck in order to convert it into a mobile load weight indicator showing in % of vehicle lifting capacity.

Every time a skid is picked up, the hydraulic pressure on the forklift is automatically activated and converted to a load weight measurement and presented to the operator.

The newer ED2-Series is digital load weight indicator showing in % of the vehicle lifting capacity.

 

 

ED2White5.jpg (34111 bytes)

                                       

  

 

Installation :
The ED2- SLL Series SkidWeigh  can be installed and calibrated by a local forklift dealer technician or end user forklift mechanic. The system is calibrated with known weights with a normal load center of 24" on the forks, raised 3" to 4" of the ground.

Technical Data :
Electrical
Voltage: 24 to 48 V DC 
Current: Operating 200 mA

Environmental :
Operating temperature -25 ºC to + 70 ºC
Water and dust resistant
Triple shock mounting bracket included

Physical :
120 x 80 x 55 mm , polycarbonate enclosure

Technology :
Micro Controller

Pressure Transducer 
Standard pressure port connection: G 1/4 , male thread standard
Pressure transducer adapter G1/4 to 1/4"-18 NPT male included in kit
Optional pressure port : M 12x 1,5 
Accuracy: +/- 0.3% of full scale
Repeatability: +/- 0.05% of full scale
Hysteresis: +/- 0.1% of full scale
Stability: +/- 0.2% full scale/yr

Temperature Information :
Compensation: 32° F to 175° F
Drift: +/- 0.03% /50 ° F
Medium: -22° F to 212° F
Ambient: 14° F to 175° F
Storage: -40° F to 212° F

Materials of Construction :
Casing: Stainless steel 1.4305 (AISI 303)

Weight :
95 grams

Shock Sensitivity :
<+/- 0.05% full scale @ 100g for 20 ms

Vibration Sensitivity :
<+/- 0.05% full scale @ 35g & 5-2000Hz

Response Time : < 0.1 ms, 10-90% FS

Frequency Limit : 150 Hz

Proof Pressure, 2,5  x range

Burst Pressure, 2,5  x range

Output, 3 wires 0 - 2,5 V DC

Protection :
Environmental:  IP67

Fault :
Reverse polarity
Over voltage
Short circuit

 

Swiss Made Pressure Sensors

Standard outside thread G 1/4 male, sealed at back DIN3852/E with pressure tip orifice 

Interference Stability Test Standard Effects
Electrostatic discharge (ESD) EN 61000-4-2                         15 kV air discharge, 6kV contact discharge No effect
High- frequency electromagnetic radiation (HF) EN 61000-4-6                 200mV, 80....1000Mz No effect
Conducted HF interferences EN 61000-4-6                      30V. 0,15...80 Mhz No effect
Fast transients (burst) EN 61000-4-4                       4kV No effect
Surge EN-6100-4-5                 Line-Line, Line-Case 500V, 12Ohm, 9µF No failure
Magnetic fields EN 6100-4-8                     30A/m, 50 Hz No effects
Insulation voltage 500 V DC ( optional 1000 V DC )  No effect
Interference emit Test standard Effects
Conducted interference Radiation from housing EN 55022                        0,15...   30Mhz                    30... 1000Mhz, 10 meters No emission

System Check Weighing Accuracy :
+/- 0.5% to 1% of forklift lifting capacity

Display :
Six digits LED

Order Number :
ED2-SLL-SkidWeigh   

 

 

 

 


 
 

 

 